Welcome to the AFP-200 manual, your comprehensive guide to understanding and operating the Notifier AFP-200 fire alarm control panel. This manual provides essential information for installation, operation, and troubleshooting, ensuring safe and effective use of the system. Designed for fire safety professionals and technicians, it covers key features, technical specifications, and step-by-step instructions to maximize the panel’s functionality and reliability.
1.1 Overview of the AFP-200 Fire Alarm Control Panel
The AFP-200 is a compact, intelligent fire alarm control panel designed for versatility and reliability. It features a modular design, combining a CPU module, power supply, and cabinet into a single unit. This panel supports up to one loop, making it suitable for a wide range of applications. Its advanced features include compatibility with various annunciators and integration with fire alarm networks. The AFP-200 is known for its cost-effectiveness and ease of use, providing a comprehensive fire safety solution. It is ideal for small to medium-sized facilities, offering robust functionality while maintaining simplicity in operation and maintenance.
1.2 Importance of the Manual for Installation and Operation
This manual is crucial for the correct installation, operation, and maintenance of the AFP-200 fire alarm control panel. It provides detailed instructions and guidelines to ensure the system functions optimally, meeting fire safety standards. Proper installation, as outlined in the manual, prevents system malfunctions and ensures compliance with regulations. Operators rely on this guide to understand normal standby operations, alarm responses, and troubleshooting procedures. Adhering to the manual’s instructions minimizes risks and ensures the system’s reliability, protecting people and property effectively. It serves as an essential resource for technicians and users, offering clear, step-by-step guidance for all aspects of system management.
1.3 Target Audience for the Manual
The AFP-200 manual is primarily intended for fire safety professionals, service technicians, and installers responsible for setting up and maintaining the system. It is also useful for system operators and building managers who need to understand the panel’s functionality. The manual provides detailed instructions for installation, operation, and troubleshooting, ensuring that users can maximize the system’s capabilities while adhering to safety standards. Whether you’re commissioning the system or performing routine maintenance, this guide offers essential insights and step-by-step procedures to ensure the AFP-200 operates effectively and reliably in various fire alarm applications.
Technical Specifications of the AFP-200
The AFP-200 is a compact, cost-effective, intelligent fire alarm control panel with a single circuit board housing the power supply and electronics, ideal for most applications.
2.1 Key Features of the AFP-200 Control Panel
The AFP-200 is a compact, intelligent fire alarm control panel designed for versatility and reliability. It features a modular design with a single circuit board housing the power supply and electronics, making it ideal for various applications. The panel supports up to 89 zones when used with compatible devices like the UDACT and includes an EIA-485 annunciator communications bus for seamless integration. Its 24VDC connections ensure reliable operation, and it is suitable for marine applications. The AFP-200 also offers advanced features such as user-friendly interfaces, robust diagnostics, and compatibility with a wide range of fire safety devices, ensuring comprehensive protection and ease of use.
2.2 Compatibility with Other Systems and Devices
The AFP-200 is designed to integrate seamlessly with a variety of systems and devices, enhancing its versatility in fire safety applications. It supports compatibility with annunciators, fire alarm networks, and monitoring systems, ensuring comprehensive coverage. The panel uses an EIA-485 communications bus and 24VDC connections, making it suitable for integration with external devices. It is also compatible with the UDACT for zone status reporting and works alongside Notifier’s NFS-3030 systems. Additionally, the AFP-200 is compatible with marine applications and can be paired with other Notifier products, providing a robust and interconnected fire safety solution for diverse environments and requirements.
2.3 Power Supply and Electronics Overview
The AFP-200 features a compact and efficient design, with its power supply and electronics integrated onto a single circuit board. This modular configuration includes a CPU module, power supply module, and cabinet, providing a complete fire control system. The panel operates on a 24VDC nominal power supply, ensuring reliable performance in various applications. Its electronics are designed to support advanced features while maintaining simplicity and durability. This integrated design makes the AFP-200 ideal for installations requiring a cost-effective, space-saving solution without compromising on functionality or safety. The system’s electronics are robust, ensuring consistent operation in diverse fire safety scenarios and environments.

Manual Structure and Content
This manual provides a comprehensive guide to the AFP-200, covering installation, operation, and troubleshooting. It includes detailed sections and appendices for easy reference and comprehensive understanding.
3.1 Sections Covered in the Manual
The manual is divided into clear sections for easy navigation. It includes installation guidelines, operating instructions, programming, and troubleshooting. Technical specifications and safety precautions are also covered. Appendices provide supplementary information, ensuring comprehensive understanding of the AFP-200 system. Each section is designed to address specific needs, from initial setup to advanced configurations, making it a valuable resource for both beginners and experienced users. The structured approach ensures that all aspects of the system are thoroughly explained, promoting safe and effective use. This organization helps users quickly find the information they need, enhancing efficiency and reducing downtime.
3.2 Appendices and Supplementary Information
The appendices provide additional resources to support the manual. Appendix A lists software type codes, while Appendix B explains status banners for the AFP-200. These sections offer quick reference guides for troubleshooting and understanding system messages. Supplementary information includes technical specifications, compatibility charts, and compliance details. The appendices also cover marine application compatibility and wiring requirements, ensuring comprehensive coverage. These resources are designed to enhance understanding and facilitate compliance with fire safety regulations. They serve as invaluable tools for technicians and professionals, providing detailed insights and practical solutions for various scenarios. This supplementary material ensures the manual remains a complete and reliable reference.
3.3 Software and Hardware Requirements
The AFP-200 requires specific software and hardware to function optimally. Software version PN 73609 or higher is necessary for compatibility with devices like the UDACT. Hardware components include a CPU module, power supply, and cabinet, forming a complete fire control system. The panel supports EIA-485 communications and 24 VDC connections. For marine applications, compatible equipment is listed in supplementary tables. Ensure all components meet fire safety regulations and are installed correctly. Refer to appendices for detailed specifications and compatibility charts. Proper software and hardware configuration ensures reliable performance and compliance with safety standards. Always verify requirements before installation or upgrades.

Installation Guidelines
Primary AC connections are made through TB7 on the AFP-200. Ensure EIA-485 annunciator communications and 24 VDC connections are properly established for reliable system operation and compliance.
4.1 Pre-Installation Requirements
Before installing the AFP-200, ensure the system meets all compatibility and regulatory standards. Verify that the software version is PN 73609 or higher for optimal functionality. Check that all hardware components, including the CPU module and power supply, are compatible with the control panel. Ensure the EIA-485 annunciator communications bus and 24 VDC connections are properly configured. Review the installation manual and supplementary documents to confirm compliance with fire safety regulations. Familiarize yourself with the wiring requirements and ensure all necessary tools and materials are available. Proper preparation ensures a smooth and safe installation process.
4.2 Step-by-Step Installation Process
Begin by mounting the AFP-200 cabinet securely, ensuring it is level and accessible. Connect the primary AC power to TB7, following the wiring diagram in the manual. Install the CPU module and power supply, ensuring proper alignment and secure fastening. Next, connect the EIA-485 communications bus for annunciator compatibility. Wire the zones and devices according to the system configuration, verifying all connections for accuracy. Power up the system and perform a self-test to ensure functionality. Finally, configure the system settings and test all zones and devices to confirm proper operation. Refer to the manual for detailed wiring and configuration instructions.
4.3 Wiring and Connectivity Instructions
Mount the AFP-200 cabinet securely, ensuring proper alignment and accessibility. Connect the primary AC power to TB7, following the wiring diagram in the manual. Install the CPU and power supply modules, ensuring all connections are secure. Wire the zones and devices according to the system configuration, verifying polarity and terminal assignments. Use the EIA-485 communications bus for annunciator connections, ensuring proper termination. Connect 24 VDC outputs for auxiliary devices, adhering to the specified voltage requirements. Test all connections to ensure integrity and proper system operation. Refer to the manual for detailed wiring diagrams and specifications to avoid errors during installation.

Operating Instructions
The AFP-200 operates in normal standby mode with the Green A.C. POWER indicator lit. Users can easily monitor zones, acknowledge alarms, and perform basic operations via the control panel interface.
5.1 Normal Standby Operation
During normal standby operation, the AFP-200 operates with the Green A.C. POWER indicator lit, indicating proper system function. The control panel continuously monitors all connected zones and devices, ensuring readiness to detect and respond to alarms. Users can view system status, monitor zone conditions, and perform routine checks through the interface. The panel remains in this state until an alarm, trouble, or supervisory condition is detected. Regular verification of indicator functionality and zone status is recommended to ensure system reliability and compliance with fire safety standards. Always follow manufacturer guidelines for operation and maintenance to prevent false alarms and ensure optimal performance.
5.2 Alarm Conditions and Responses
The AFP-200 detects alarm conditions through its intelligent monitoring of connected zones and devices. Upon detection, the system activates visual and audible alerts, providing clear indication of a fire, trouble, or supervisory condition. The control panel displays detailed information about the affected zone, enabling quick identification and response. In alarm mode, the panel logs events and triggers connected devices such as annunciators or monitoring systems. Users must follow established emergency procedures to address the situation safely. Proper training and familiarity with the system are essential for effective response. Always refer to the manual for specific instructions on handling different alarm scenarios and ensuring compliance with safety protocols.
5;3 Troubleshooting Common Issues
The AFP-200 includes advanced diagnostic tools to identify and resolve common issues. Error codes and status banners provide clear indicators of system malfunctions, such as power supply faults or zone troubles. Users can access detailed logs to pinpoint the source of the problem. Common issues include faulty wiring, sensor malfunctions, or software glitches. Refer to the troubleshooting section in the manual for step-by-step solutions. Always ensure the system is powered down before performing physical inspections or repairs. If issues persist, consult the manual or contact certified support for assistance. Regular maintenance and updates can prevent many common problems, ensuring optimal system performance and reliability.

Programming and Configuration
Configure the AFP-200 by setting up zones, devices, and user permissions. Advanced options enable customization of system settings for tailored fire safety solutions, ensuring optimal performance and security.
6.1 Setting Up Zones and Devices
Setting up zones and devices on the AFP-200 involves defining detection zones and assigning devices such as smoke detectors, pull stations, and horns. Use the control panel or software tools to configure zone settings, ensuring proper system functionality. Assign unique identifiers to each device and zone for easy monitoring. Configure zone types (e.g., supervisory, alarm) and sensitivity levels based on application requirements. Proper setup ensures reliable detection and response to fire events, maintaining safety and compliance with fire safety standards. Refer to the manual for detailed instructions on zone configuration and device integration.
6.2 User Permissions and Passwords
Managing user permissions and passwords on the AFP-200 ensures secure access to the system. Assign different access levels, such as administrator, operator, or technician, to control user functionality. Administrators can set passwords and permissions, restricting access to critical functions. Use strong, unique passwords and update them regularly for enhanced security. The system allows multiple user accounts, each with specific privileges, ensuring only authorized personnel can modify settings or view sensitive data. Refer to the manual for detailed steps on configuring user permissions and passwords, ensuring compliance with fire safety regulations and maintaining system integrity.
6.3 Advanced Configuration Options
The AFP-200 offers advanced configuration options to tailor the system to specific needs. Configure zone mappings, notification protocols, and integration settings for seamless operation. Customize alarm priorities, delay timers, and system responses to align with fire safety protocols. Utilize the panel’s programmable inputs and outputs to enhance functionality. Advanced features include network integration, remote monitoring, and custom event logging. Refer to the manual for detailed steps on configuring these options, ensuring optimal performance and compliance with safety standards. Proper setup of these features is crucial for reliable operation and effective emergency response.

Integration with Other Systems
The AFP-200 seamlessly integrates with annunciators, fire alarm networks, and monitoring systems, enhancing its functionality and connectivity. Proper setup ensures reliable communication and coordinated responses during emergencies.
7.1 Compatibility with Annunciators
The AFP-200 is designed to work seamlessly with compatible annunciators, ensuring clear communication and status reporting. The system supports the EIA-485 communications bus and requires a 24 VDC connection for proper operation. When integrated with a UDACT (Universal Digital Alarm Communicator Transmitter), the AFP-200 can monitor up to 89 zones, providing detailed alarm notifications. For optimal performance, refer to Appendix B of this manual and the UDACT manual for specific wiring and configuration instructions. Proper setup ensures reliable communication between the AFP-200 and connected annunciators, enhancing overall system functionality and emergency response capabilities.
7.2 Integration with Fire Alarm Networks
The AFP-200 seamlessly integrates with fire alarm networks, enabling enhanced system scalability and coordination. It supports connection to Notifier’s NFS-3030 and NFS-3030E systems, ensuring compatibility and reliable communication. The panel’s network capabilities allow for centralized monitoring and control of multiple fire alarm systems, streamlining emergency response. Proper network configuration requires adherence to the guidelines outlined in this manual, including setup procedures and troubleshooting tips. This integration ensures that the AFP-200 operates efficiently within larger fire safety networks, providing comprehensive protection and meeting the needs of complex facilities. Refer to the manual for detailed instructions on network setup and optimization.
7.3 Connection to Monitoring Systems
The AFP-200 can be connected to monitoring systems for real-time status updates and remote supervision. This connection enables monitoring centers to receive alerts and alarms, ensuring prompt responses to emergencies. The panel supports communication via EIA-485 and other compatible protocols, facilitating integration with central monitoring stations. Proper setup requires configuring the panel’s communication parameters and ensuring compatibility with the monitoring system’s requirements. Refer to the manual for detailed instructions on wiring, protocol settings, and troubleshooting common issues. This integration enhances system reliability and ensures comprehensive monitoring, critical for large-scale fire safety applications. Always follow the manual’s guidelines for a secure and efficient connection.
Appendices and References
The appendices provide supplementary information, including software type codes, status banner explanations, and additional resources. These sections offer detailed technical data and further documentation for advanced configurations and troubleshooting.
8.1 Software Type Codes
Software type codes are essential for identifying compatible software versions for the AFP-200. These codes ensure proper system functionality and are detailed in Appendix A. They help users verify software compatibility, especially when integrating devices like the UDACT, which requires specific versions for optimal performance. Referencing these codes prevents installation issues and ensures all components work seamlessly together. Always cross-check codes with the manual before updating or installing software to maintain system integrity and reliability.
8.2 Status Banners Explanation
Status banners on the AFP-200 display critical system information, such as active alarms, faults, or normal operating conditions. These banners provide real-time updates, ensuring users are informed about the system’s current state. For example, a “NORMAL” banner indicates all systems are functioning correctly, while an “ALARM” banner signals an active fire event. Refer to Appendix B for a detailed explanation of all possible status banners and their meanings. Understanding these indicators is crucial for quick response and system management, helping users identify issues and take appropriate actions efficiently.
8.3 Additional Resources and Documentation
For comprehensive understanding, the AFP-200 manual is supported by additional resources and documentation. These include detailed appendices, such as Appendix B, which explains status banners and their interpretations. Supplementary guides like the UDACT manual provide in-depth information on specific components and their integration. Online resources, such as PDF manuals and technical bulletins, are available for download, offering updated information and troubleshooting tips. These materials ensure users have access to all necessary tools for effective system operation and maintenance. Referencing these resources enhances your ability to manage and troubleshoot the AFP-200, ensuring optimal performance and compliance with safety standards.
Safety Precautions
Always disconnect power before servicing. Use proper tools and avoid live circuits. Follow fire safety codes and wear protective gear. Ensure proper grounding for safety.
9.1 Handling Electrical Components
When handling electrical components of the AFP-200, always disconnect power first. Use insulated tools to avoid shock. Ensure proper grounding and wear protective gear. Never touch live circuits. Follow manual guidelines for safe servicing and avoid damaging sensitive electronics. Proper handling prevents system malfunctions and ensures user safety. Always refer to the manual for specific procedures and precautions.
9.2 Compliance with Fire Safety Regulations
The AFP-200 is designed to meet fire safety regulations and standards. Ensure all installations comply with local fire codes and NFPA requirements. Regular inspections and testing are mandatory to maintain compliance. Adhere to manufacturer guidelines for system operation and maintenance. Familiarize yourself with regulatory updates to ensure ongoing adherence. Proper compliance ensures reliable performance and safety. Always follow certified procedures for installations and modifications. Compliance with fire safety regulations is critical for system effectiveness and legal requirements. Refer to local authorities for specific compliance standards and certifications. The AFP-200 is engineered to support fire safety regulations, providing a reliable solution for fire alarm systems.
9.3 Emergency Procedures
In emergency situations, the AFP-200 provides clear alarm indicators and audible signals to alert occupants. Ensure all personnel are trained to respond promptly. Upon activation, evacuate the premises and follow established emergency protocols. Use the emergency key to silence alarms if necessary, but only after verifying the situation. Reset the system only when safe to do so. Familiarize yourself with the manual’s emergency operation section for detailed procedures. Regular drills and training are essential to ensure effective response. Always prioritize safety and adhere to the system’s guidelines for emergency conditions. The AFP-200 is designed to support swift and reliable emergency actions.

Troubleshooting and Maintenance
Regular maintenance ensures optimal performance. Check for faults, clean components, and update software. Use diagnostic tools to identify issues. Refer to the manual for detailed solutions.
10.1 Common Issues and Solutions
Common issues with the AFP-200 include error codes, communication failures, and power supply problems. For error codes, refer to the status banners in Appendix B. Communication issues may stem from faulty wiring or outdated software. Ensure all connections are secure and software is up-to-date. Power supply problems can be resolved by checking the AC connections and ensuring the battery is fully charged. For detailed troubleshooting, consult the diagnostic tools section. Always follow safety precautions when handling electrical components. Regular maintenance and updates can prevent many of these issues. Refer to the manual for specific solutions and guidelines.
10.2 Routine Maintenance Requirements
Regular maintenance is crucial for optimal performance of the AFP-200. Inspect the power supply, battery, and wiring quarterly to ensure reliability. Clean the panel and components to prevent dust buildup. Verify software updates and ensure compatibility with connected devices. Test alarm functionality and communication systems monthly. Check error logs and address issues promptly. Replace batteries every 5 years or as indicated by self-testing. Refer to the manual for detailed procedures and schedules. Proper maintenance ensures compliance with fire safety regulations and prolongs system lifespan. Always follow safety guidelines when performing maintenance tasks.
10.3 Diagnostic Tools and Techniques
The AFP-200 features advanced diagnostic tools to identify and resolve issues efficiently. Utilize the system’s error logs and LED indicators to pinpoint faults. The manual provides detailed troubleshooting guides and diagnostic codes for quick reference. Perform regular self-tests to ensure all components function correctly. Use the system’s software to monitor real-time status and configure settings. For complex issues, refer to the diagnostic procedures outlined in the manual or consult supplementary documentation. These tools enable technicians to identify and address problems promptly, ensuring system reliability and compliance with safety standards. Regular use of these diagnostic features helps maintain optimal performance and minimizes downtime.
The AFP-200 manual is a crucial resource for installing, operating, and maintaining the system. It provides comprehensive guidance, ensuring optimal performance and compliance with safety standards. Regular updates are essential for maximizing functionality and safety.
11.1 Summary of Key Points
The AFP-200 manual provides a detailed guide for installing, operating, and maintaining the Notifier AFP-200 fire alarm control panel. It covers technical specifications, installation requirements, and troubleshooting procedures. The manual emphasizes the importance of regular updates and adherence to safety standards. Key features include compatibility with various systems, robust power supply, and advanced configuration options. Intended for professionals, it ensures optimal performance and compliance with fire safety regulations. By following the manual, users can effectively manage and maintain the AFP-200, ensuring reliable fire protection and alarm responses. Regular updates and proper maintenance are crucial for sustained functionality and safety.
11.2 Final Tips for Effective Use
For optimal use of the AFP-200, ensure regular software updates to maintain peak performance. Always follow installation and maintenance guidelines to prevent system malfunctions. Familiarize yourself with the control panel’s interface to streamline operations during emergencies. Refer to the manual for troubleshooting common issues promptly. Regularly inspect wiring and connections to ensure reliability. Train all users on alarm conditions and response protocols. Keep backup power sources ready to avoid downtime. Adhere to fire safety standards and local regulations for compliance. By following these tips, you can maximize the AFP-200’s effectiveness and ensure a safe, reliable fire alarm system.
11.3 Importance of Regular Updates
Regular updates are crucial for maintaining the AFP-200’s performance and security. Software updates often include bug fixes, enhanced features, and compatibility improvements. Failing to update can lead to system malfunctions or vulnerabilities. Always check the Notifier website for the latest software versions and follow the manual’s update instructions. Outdated software may cause compatibility issues with newer devices or systems. Updates ensure compliance with evolving fire safety standards and regulations. By keeping the AFP-200 up-to-date, you guarantee reliable operation, improved functionality, and enhanced safety. Regular updates are essential for maximizing the system’s effectiveness and protecting your facility from potential risks.